| Lightweight equipment frame | Low mass, adequate bending stiffness, and resistance to local damage at clamps or joints. | Outside diameter: about 20–40 mm Wall thickness: about 1–2 mm | A balanced layup with fibers in axial and off-axis directions can support bending and handling loads. | Check maximum deflection, unsupported length, impact exposure, and how loads enter the tube. |
| Mast, boom, or long support pole | Bending stiffness, low deflection over a long span, and resistance to buckling under compression. | Outside diameter: about 30–80 mm Wall thickness: about 1.5–3 mm | Axial fibers contribute to stiffness; off-axis and hoop reinforcement can help resist splitting and local loads. | Evaluate span, end supports, wind or side loads, buckling, and any telescoping-fit requirements. |
| Rotating drive shaft | Torsional stiffness, fatigue resistance, low mass, and acceptable balance at operating speed. | Outside diameter: about 20–100 mm Wall thickness: about 1.5–4 mm | Off-axis fibers, often near ±45°, are important for carrying torsional loads; axial plies may also be needed. | Specify torque, speed, cyclic duty, critical speed, attachment design, and balance requirements. |
| Robotic arm or moving link | High stiffness-to-mass performance, controlled deflection, and durability around mounting points. | Outside diameter: about 15–50 mm Wall thickness: about 1–3 mm | A multi-directional layup may suit combined bending and torsion; local reinforcement can be needed at joints. | Check acceleration loads, vibration, fastener loads, bearing interfaces, and fatigue over the expected cycle life. |
| Air or fluid conveyance tube | Required pressure capacity, leak resistance, chemical compatibility, and reliable end connections. | Outside diameter: about 10–50 mm Wall thickness: about 1–2 mm | Hoop and axial reinforcement must match the pressure and end-load conditions; a liner or sealed inner surface may be required. | Do not assume a general-purpose structural tube is pressure-rated. Require design calculations, suitable fittings, and pressure testing. |
| Electrical support or insulating structure | Electrical isolation, mechanical strength, and performance in the intended moisture and temperature conditions. | Geometry depends on the support load; specify diameter and wall thickness from the mechanical design. | Carbon fiber is electrically conductive. Where electrical insulation is essential, consider a glass-fiber composite tube instead. | Confirm voltage, creepage and clearance needs, moisture exposure, and applicable electrical safety requirements. |